1. Sadoon Ayed, Univerzitet u Nišu, Mašinski fakultet, Serbia
2. Milos Jovanovic, Univerzitet u Nišu, Mašinski fakultet, Serbia
3. Gradimir Ilić, Univerzitet u Nišu, Mašinski fakultet, Serbia
4. Predrag Živković, Univerzitet u Nišu, Mašinski fakultet, Serbia
5. Mića Vukić , Univerzitet u Nišu, Mašinski fakultet, Serbia
6. Mirko Dobranjac, University of Banja Luka, Faculty of mechanical engineering,
Republic of Srpska, Bosnia and Herzegovina
7. Suzana Klječanin, The Public Institution Institute for materials and construction testing of Republic of Srpska,
Republic of Srpska, Bosnia and Herzegovina
Measurements of temperature distribution were performed in a rectangular tank with aspect ratios 4x2x1, using different working fluids. The experimental setup was adjusted taken to be as close to real fuel tanks exposed to solar radiation, as in airplane wings. The measurements were taken at fifteen different positions on the faces of the tank. Probes used are PT100 elements. As to obtain as uniform temperature as possible, double bottom was used, with water as medium for obtaining of the constant surface tmperature. The results are compared with the those obtained by IR camera.
Ključne reči :
Tematska oblast:
Datum:
16.02.2013.