1. Huda Hajjir Karcic,
Federation of Bosnia and Herzegovina
, Bosnia and Herzegovina
PURPOSE:
To establish incidence of posterior capsule opacification (PCO) and its correlation with implanted intraocular lens (IOL).
METHODS:
In this 3-years prospective study, the same surgeon performed standard phacoemulsification in patients who were randomized and divided into three groups:
- group 1: patients with AcrySof® IQ IOL (Model SN60WF) implantation
- group 2: patients with SENSAR® Acrylic IOL implantation
- group 3: patients with Akreos AO (model AO60) implantation
Each group had 30 patients,with no history of any metabolic desease.
In two years follow up we evaluated visual aquity, PCO and patient\'s satisfaction.
RESULTS:
After two years follow up PCO incidence in group 1 was 1%, in group 2 10% and in group 3 8%.
Visual acuity and patients satissfaction follow up after one month, one year and two years are graphicly presented.
CONCLUSION:
After two years, patients in group 1 had less PCO incidence, better visual aciuty and were more satisfied than patient in other groups.
Кључне речи :
Тематска област:
katarakta
Уводни рад:
Да
Датум:
04.04.2012.
Бр. отварања:
700